4.0 Operating instructions

4.1 General

As mentioned at the beginning of this manual, you should never operate a

lasher unless you’ve been properly trained in advance or are being directed by

a properly trained linesperson who is responsible for your work. However,

you should find this section of the book helpful in outlining the correct se-
quence of steps to take in using your Apollo lasher.

4.2 Preparing a lashing wire coil

The first step in any lashing oper-

ation is to prepare the lashing

wire coil. Note: It is important

that the lashing wire is loaded

properly to ensure proper lasher

operation.

1. If the lashing wire is wrapped

with wire ties, rotate the head of the

wire tie attached to the looped end of

the lashing wire to the center of the

coil (see figure 4). This will facilitate

the cutting of the wire tie in a later

step and help ensure that the com-

plete wire tie is removed.

2. Do not cut all of the cable ties! Leave the cable tie attached to the

looped end of the lashing wire, and cut the remaining 3 cable ties

on the lashing wire coil.

3. Cut the looped end of the wire on the inside diameter of the wire

coil. This step will help in the loading of the coil onto the hub and

subsequent steps.


4.3 Install the prepared wire coil

The proper installation of the wire coil is a must for hassle-free

lashing. Many of the problems in lashing can be traced to improper

preparation of the lashing wire coil.

1. Open the cover with a screw- driver

or 7/16 in. socket as found on the

216C tool, or any tool used to tighten

the bugnut. Turn the fastener 1/4

turn (counter-clock wise) until the

fastener unseats. The spring loaded

cover should open to expose the lash-

ing wire reel.

Figure 4

Figure 5

Advertising