General Machine Products Co., Inc.

PRECAUTIONS

Position the stationary reel at or near a pole carrying suitable
power company vertical neutral of a multi-grounded neutral
(MGN) system
or nearby grounded communications plant that
meet the provisions. (As described on page 4, in the MGN para-
graph) (ie. Strand wire or un-insulated guy wires).

Do not make ground connections above the space allocated for
telephone, attachments on the pole.

Test any vertical power ground conductor to which the
grounding roller is to be connected using a voltage
tester.



The grounding of
strand, using the
grounding roller, shall
be considered as
supplemental to, and
not as a substitute
for, insulating gloves
and other protective
measures as shown.