Wall Construction

ENGINEERED WOOD CONSTRUCTION GUIDE

FORM NO. B360P

© 2011 APA – THE ENGINEERED WOOD ASSOCIATION

WWW.APAWOOD.ORG

52

Min. 3/8

Performance

Category

APA RATED

SHEATHING

nailed to studs

with 6d common

nails spaced

6" o.c. along panel

edges and 12" o.c.

at intermediate

supports*

*See

Table 5

for

nail dimensions

Supports 16"

or 24" o.c.

FIGURE 14

APA PANEL CORNER BRACING

Any wall

sheathing

For additional information on wall bracing,

see

Introduction to Wall Bracing, Form F430

.

APA RATED

SHEATHING

Brick veneer

or masonry

FIGURE 15

BRICK VENEER OVER APA PANEL SHEATHING

“Weep holes”

in bottom

course

every 24"

Extend flashing up behind

weather-resistive barrier at least 6"

Building paper or other

code-recognized weather-

resistive barrier

required

1" air space

Hold panel edge 1/2"

above base flashing

APA Panel Wall Sheathing

APA RATED SHEATHING meets building code wall sheathing require-
ments for wind pressures and wall bracing. Even when foam or other
nonstructural sheathing is used, APA RATED SHEATHING corner brac-
ing panels (Figure 14) of the same thickness meet code wall bracing
requirements. Installation recommendations are given in Figure 13 and

Table 24.

Recommended wall sheath-
ing spans with brick veneer or
masonry are the same as those
for panel sheathing (see Table
24). See Figure 15 for installa-
tion recommendations.

Panel recommendations for
preframed wall sections are the
same as for built-in-place walls.

Note: To minimize the potential

for panel buckling, gluing of wall

sheathing to framing is not recom-

mended, except when recommended

by the adhesive manufacturer for

wall sheathing that already has been

permanently protected by siding.

1/8" spacing is

recommended

at all edge and

end joints unless

otherwise indicated

by panel

manufacturer

Filler strip

if required

APA RATED

SHEATHING

applied with

strength axis

parallel to

studs

APA RATED

SHEATHING

applied with

strength axis

across studs

(a)

Siding

6" minimum

clearance,

siding to grade

FIGURE 13

APA PANEL WALL SHEATHING

Building paper

or other code-

recognized

weather-

resistive

barrier

(a) Check local building

codes for blocking requirements

between studs for braced or engineered

shear wall segments, when wall sheathing

is installed horizontally across studs.