1.8 Functional Verification

The RSH-600 is equipped to operate on a 115 V (ac), 60 Hz line or a 24 V (dc)
supply depending on the model number. You can verify the required voltage on the
body of the pneumatic valve mounted on the side of the RSH-600. The RSH-600
may be bench checked using the following procedure:

1

Connect air pressure (55 psi) via 1/4 in. plastic tubing to the air inlet fitting at
the base of the solenoid valve marked P.

2

Connect the RSH-600 as shown in

Figure 1-4

or any convenient method of

applying and removing the control voltage. The RSH-600 will advance when
the voltage is applied and latch into position when it is removed. The electrical
pulse duration should be at least one second.

Figure 1-4 Electrical Connection

Control

Voltage

115 V (ac)

or

24 V (dc)

J1

RSH

Switch