4.3.1
Adjusting the Setpoints SP1, SP2
The switching characteristics and the hysteresis can
only be programmed via 
• the diagnostic port (→  [3]) 
• the DeviceNet, Profibus, EtherCAT and RS485 
interface (
→  [3], [4], [5], [6]).
The thresholds of the setpoints can be adjusted via
• the buttons on the gauge 
• the diagnostic port (→  [3]) 
• the DeviceNet, Profibus, EtherCAT and RS485 
interface (
→  [3], [4], [5], [6]).
If both a High Trip Point and a Low Trip Point are
assigned to a setpoint, Low Trip Point only can be 
adjusted via the corresponding button on the gauge. 
DANGER
DANGER: malfunction 
If processes are controlled via the signal output, 
keep in mind that by pushing an <SP> button the 
measurement signal is suppressed and the cor-
responding threshold value is output instead. This 
can cause malfunctions. 
Push the <SP> button only if you are sure that no 
damages can arise from a malfunction.