Johnson Systems DE90-3000 Series Retrofit Control System User Manual

Page 16

Advertising
background image

www.johnsonsystems.com

16

Normally

Open

Thermostat

Switch

Overtemp

Input

Normally

Open

Common

+12V

100mA

Max

Open

Collector

Output

Maintained

Normally

Open

Switch

Contact

Common

Fire

Alarm

Input

Maintained

Normally

Open

Switch

Contact

Common

Security

Alarm

Input

Maintained

Normally

Open

Switch

Contact

Common

Auxiliary

Input

Over-Temp Input (Normally Open)

• Terminate (OVERTEMP INPUT (NO)) on J5 connector.

• Disables all dimmer outputs when contact/switch is closed.

• Controlled via a maintained contact/switch to low-voltage common

(COMMON).

Fire Alarm Input (Normally Open)

• Terminate (FIRE INPUT (NO)) on J5 connector.

• Triggers selected channels to turn on when contact/switch is closed.

• Controlled via a maintained contact/switch to low-voltage common

(COMMON).

• Programmed in the “F-ALARM” menu. See page

31

for details.

Security Alarm Input (Normally Open)

• Terminate (SECURITY INPUT (NO)) on J5 connector.

• Triggers selected channels to cycle on and off at a 1 Hertz rate when

contact/switch is closed.

• Controlled via a maintained contact/switch to low-voltage common

(COMMON).

• Programmed in the “S-ALARM” menu. See page

31

for details.

Auxiliary Input (Normally Open)

• Terminate (AUXILIARY INPUT (NO)) on J5 connector.

• Triggers 1 of 24 presets when contact/switch is closed.

• Controlled via a maintained contact/switch to low-voltage common

(COMMON).

• Programmed in the “AUX IN” menu. See page

30

for details.

Open Collector Output

• Terminate (OPEN COLLECTOR INPUT (NO)) on J5 connector.

• Sink up to 100mA.

• Trigger Solid State Relays (SSR) or other external devices.

• Controlled via DMX and/or Analog Input 4.

• Programmed in the “OC MODE” menu. See page

30

for details.