Johnson Systems DE90-3000 Series Retrofit Control System User Manual

Page 30

Advertising
background image

www.johnsonsystems.com

30

25. TEST INC

Set the test increment units to percent or hexadecimal.

The levels for the dimmer test (DIM TEST) and analog test (ANA TEST) features can be

displayed as a percentage or hexadecimal value.

PERCENT

Press EXECUTE to toggle test increments from PERCENT to HEX VAL.

HEX VAL

Press EXECUTE to toggle test increments from HEX VAL to PERCENT.

Any change in the configuration is automatically saved.

26. OC MODE

Configure the input trigger parameters for the open collector output.

The on-board open collector output is used to sink up to 100mA of current. It can be

configured to be triggered via a selected DMX channel, analog input 4, or both. The open

collector is triggered on at 55% control input and triggered off again at 45% control input.

When analog and DMX (A+D) is selected to trigger the open collector the inputs are

combine for highest takes precedence (HTP).

Press EXECUTE to enter the menu and configure the open collector output.

A+D< 001

Displays the active trigger mode as analog and DMX (A+D<) channel 001.

A+D> 001

Press EXECUTE to toggle the pointer (>) and select the DMX channel.

A+D> 512

Press MENU (

) to change and select the DMX channel from 001 to 512.

A+D< 512

Press EXECUTE to toggle the pointer (<) and select a different trigger mode.

DMX< 512

Press MENU (

) to select DMX input trigger mode.

ANA<

Press MENU (

) to select analog (ANA) input trigger mode.

OFF<

Press MENU (

) to deactivate (OFF) the open collector output.

Press ESCAPE to exit the menu and save the desired settings.

Press RESET to exit the menu without saving.

The menu will automatically timeout after 2 minutes of inactivity and save.

27. AUX IN

Select which scene the auxiliary input will trigger/enable.

When a contact is sensed on the auxiliary input the selected scene will be triggered and

held until the contact is removed. The auxiliary input only functions when scene mode

(SCENESET) is activated or when the systems local buttons (L-BUTTONS) are set for

scene mode.

SCENE:01

Displays the scene (01) that will be triggered by the auxiliary input.

SCENE>01

Press EXECUTE to enter the menu and select a different scene.

SCENE>24

Press MENU (

) to change the selected scene from 01 to 24.

Press ESCAPE to exit the menu and save the desired scene to be triggered.

Press RESET to exit the menu without saving.

The menu will automatically timeout after 2 minutes of inactivity and save.

28. L-BUTTON

Set the mode of the local buttons to scene, bump or disabled.

DE90-3000 Series retrofit control systems normally have the local buttons disabled.

Bump mode is used in conjunction with 24 bump button switches, not applicable with

DE90-3000 Series retrofit control systems.

Setting the local buttons to scene mode puts the system in scene mode. With scene

mode enabled the selected scene will always be activated when DMX is not being

received.

The selected scene can be changed in the SCENESET menu. Scene mode enables

the use of the auxiliary (AUX) input. A contact closure sensed on the over- temperature

(O/T), fire alarm (FIRE) or security alarm (SCTY) input automatically takes precedence

over scene mode.

DISABLED

Press EXECUTE to toggle the operation of the local buttons to disabled.

BUMP

Press EXECUTE to toggle the operation of the local buttons to bump mode.

SCENE

Press EXECUTE to toggle the operation of the local buttons to scene mode.

Any change in the configuration is automatically saved.