• The inner metal panel can now be carefully set into place and secured

using the eight (8) #8-18 x 1/2" mounting screws provided. Two (2) #8

speed clips are provided to replace any missing or damaged.

WARNING! Never connect (turn on) power with inner metal panel removed.

• Connect (turn on) the power supply to the Strand DE90 dimmer rack.
• Verify the operation of the system status LED indicators, LCD display

and programming switches. Refer to page 18 to 20 for details.

• Refer to the programming section of this manual for system

configuration. Refer to page 22 to 37 for details.

• Test the system thoroughly to ensure all wiring terminations are

functioning.

• Verify all of the dimmer control outputs have the correct phase

referencing. If a dimmer control output is patched to the incorrect phase

reference, the dimmer will not dim correctly and will go to full output

at around 1% DMX input. The factory configuration for DE90-3000

Series retrofit systems is for three-phase applications. The defaults

(DEFAULTS) menu is used to reconfigure the phase patch for standard

single-phase applications and the phase patch (Ø-PATCH) menu is

used to configure non-standard applications. Refer to page 31 and 36

for programming details. Refer to the charts on page 8 for the standard

dimmer to phase patch configuration for DE90 dimmer racks.

• Verify all dimmers are controlled sequentially. The Dimmer to Channel

Patch (DC-PATCH) will need to be modified (programmed) to

compensate for a mixture of single, dual and quad dimmer modules.

Refer to page 27 for programming details. Examples of DC-PATCH

configurations can be found on page 9 and 10. Charts used to

determine the DC-PATCH can be found on page 11 and 12.

• Verify fan operation. The fans are triggered on at 6% DMX input control,

and stay on as long as the DMX is at 6% or greater. When the DMX

input is brought down below 6%, there is a 5 minute timeout for the fans

to turn off. When the Panic Switch is turned on the fans turn on; when

the Panic Switch is turned off the fans turn off.

• Verify Front Panel (Faceplate) Panic Switch operation. When the Panic

Switch is turned on, all of the dimmer outputs are full-on.

• Verify Front Panel (Faceplate) DMX-B Input operation. The DMX B

LED will illuminate and the LCD will show the number of DMX channels

received.

• Once the DE90-3000 retrofit system has been thoroughly tested the

dimmer rack door can be carefully set back on the hinges and closed.