Analog outputs
Digital outputs (only for types 707021/... and 707022/...)
Current output
Output range
proportional DC current 0 — 20mA or 4 — 20mA programmable
Accuracy
± 0.015mA
Linearity error
± 0.005mA
Max. burden
750
Burden error
± 0.01mA
Ripple
± 1% referred to 20mA, 0 — 90kHz; above 90kHz: tested to EN 50081
Output current on probe break,
over/underrange
0mA or 22mA (programmable)
Voltage output
Output range
0 — 10V or 2 — 10V
Accuracy
± 5mV
Linearity error
± 2mV
Load resistance
2k
Burden error
± 15mV
Ripple
± 1% referred to 10V, 0 — 90kHz
Output voltage on probe break,
over/underrange
0V or 11V (programmable)
2 open-collector outputs
Output 1
lk7 or lk8 or fault output
Output 2
lk7 or lk8 or frequency output
Function lk7
Function lk8
Switching capacity of open-collector
35V, 100mA
Voltage drop
in switched condition
1.2V
Short-circuit strength
not available
Frequency output
Function
the frequency output produces the latest measurement as a frequency;
the frequency at range start/end is programmable
Smallest / highest frequency
10Hz / 1000Hz
Error output
Activation
due to probe break, over/underrange and
internal errors (Pt100 of cold junction faulty, EEPROM does not respond)