Data sheet 90.2910

Page 2/4

JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14,

36039 Fulda, Germany

Postal address:

36035 Fulda, Germany

Phone:

+49 661 6003-0

Fax:

+49 661 6003-607

E-mail:

[email protected]

Internet:

www.jumo.net

JUMO Instrument Co. Ltd.
JUMO House
Temple Bank, Riverway
Harlow - Essex CM20 2DY, UK
Phone: +44 1279 63 55 33
Fax:

+44 1279 63 52 62

E-mail:

[email protected]

Internet: www.jumo.co.uk

JUMO Process Control, Inc.
8 Technology Boulevard
Canastota, NY 13032, USA
Phone:

315-697-JUMO
1-800-554-JUMO

Fax:

315-697-5867

E-mail:

[email protected]

Internet: www.jumo.us

CAN transducer

Protocol

CiA DS 301, V4.02, CANopen Slave

Profile

CiA DS 404, V1.2 Measuring Devices and Closed-Loop Controllers

Baud rate

20kBaud to 1MBaud, setting via LSS or SDO

Module ID

1 to 127, setting via LSS or SDO

PDO

0 Rx, 1 Tx

SDO

1 Rx, 1 Tx

Emergency

yes

Heart Beat

yes

LSS

yes

SYNC

yes

Operation, project planning

All parameters are accessible via the CANopen object directory (EDS) and configurable via standard
CANopen software tools.

Input

Measurement input

Pt 1000 DIN EN 60 751, Class B

Measurement range limits

-50 to +150°C / -50 to +450°C

Measurement rate

250ms

Output

Output signal

CANopen per CiA DS 404 V1.2, in °C, can be changed to °F, K
Decimal place selectable 0, 1, 2

Transmission behavior

temperature linear

Electrical connection

Round plug M12x1, 5-pin per IEC 60 947-5-2

Voltage supply

Voltage supply

DC 10 to 30V

Current consumption

max. approx. 45mA

Monitoring

Measuring circuit
- Measured value underrange (freely selectable lower limit)
- Measured value overrange (freely selectable upper limit)
Probe short-circuit
Probe break

Additional functions

min./max. measured value memory

Precise adjustment

Change-over °C, °F, K

Decimal places selectable 0, 1, 2

Environmental influences

Operating temperature range

-20 to +85°C

Storage temperature range

-40 to +85°C

Temperature influence

≤ ± 0.0025% / K Deviation from 22°C of the measuring range span

Accuracy

Class B per DIN EN 60 751 max. ± 0.2% of the measuring range span

EMC

EN 61 326

Emitted interference, interference
resistance

Class B, industrial standard

Mechanical shock

per DIN IEC 68-2-27

EL 50mm -> 50g / 3ms; EL 100mm -> 30g / 3ms

(for type 902910/10)

EL 200mm -> 15g / 3ms

Mechanical vibrations

per DIN IEC 68-2-6

EL 50mm max. 10g at 10 to 2000Hz

(for type 902910/10)

EL 100mm max. 5g at 10 to 300Hz
EL 200mm max. 2g at 10 to 100Hz

Protection class

IP67, per EN 60 529, with connection plug screwed on