WARNINGS AND ALARMS

STEP 1

Seed Rate Alarm - A seed rate alarm is activated

whenever row average seed population drops below

threshold set for that row.

Corresponding row on bargraph starts flashing and

monitor emits a series of beeps that persist until

alarm is cleared or ACK button is pressed. ‘‘Seed

Rate Alarm’’ appears in upper left corner of screen.

Bargraph for row drops down based on threshold

set for alarm.

EXAMPLE: If threshold is 70%, lower two bargraph segments

are shown. If threshold is 50% or 10%, lowest bargraph

segment is shown.

Status message associated with an alarm contains

more information about the alarm. To view ‘‘Status

Message’’ for a seed rate alarm, press F1 key next

to Status.

If sensor detects no seed flow it displays which

row is not functioning. Alarm may be caused by

a mechanical problem reducing seed flow or an

electrical problem causing an incorrect seed count.

NOTE: Only way to remove an alarm is to find problem and

correct it. Alarms are not reported for rows with seed rate

alarm thresholds disabled.

NOTE: Percentage shown in alarm message is percentage at

time alarm occurred.

Row can be removed by pressing F2 key next to

Remove. A box appears asking for confirmation to

remove row. “OK” box is highlighted in box.

Press knob or Enter key to confirm removal. Sensor

Setup screen displays “none” next to the row that

was removed. Press F6 key next to “Done”. The

setup mode screen will appear.

RowPop

Spacing

Area

Other

Accuracy

MPH

Avg
Pop

0

0.0

1 2 3 4 5 6 7 8 9 10 11

1 2 3 4 5 6 7 8 9 10 11 12

120

110

100

90

80

70

60

%

120

110

100

90

80

70

60

%

Seed Rate Alarm

Setup Mode

Install

Remove

Ignore

Revive

Done

Rear Row 1 OK
Rear Row 2 OK

Rear Row 3

OK

Rear Row 4 OK
Rear Row 5 OK

Rear Row 7 OK

Rear Row 8

OK

Rear Row 9 OK

Rear Row 10

OK

Rear Row 11 OK

View

Sensor Setup

[Auto Detect]
[Seed Sensors]

Seed Rate Alarm

Rear Row 6 OK

Setup Mode

Install

Remove

Ignore

Revive

Done

Rear Row 1 OK
Rear Row 2 OK

Rear Row 3

OK

Rear Row 4 OK
Rear Row 5 OK

Rear Row 7 OK

Rear Row 8

OK

Rear Row 9 OK

Rear Row 10

OK

Rear Row 11 OK

View

Sensor Setup

[Auto Detect]
[Seed Sensors]

Seed Rate Alarm

Rear Row 6 OK

OK to Remove Rear Row 6?

Confirm Remove

Cancel

OK

Setup Mode

Install

Remove

Ignore

Revive

Done

Rear Row 12 OK

Rear Row 11 OK

Rear Row 13 OK

Rear Row 14

OK

Rear Row 15 OK
Rear Row 16 OK

Front Row 2 OK
Front Row 3 OK
Front Row 4 OK
Front Row 5 OK
Front Row 6 OK
Front Row 7 OK

View

Sensor Setup

Front Row 1 none

Press F2 key next to Plant to return to Planter

Configuration screen.

STEP 2

Section Not Planting - If monitor detects an entire

section not planting, three beeps sound. Affected

section bargraph flashes and is reduced to lowest

segment. An alarm message is added to list of

‘‘Status Messages’’. Press F1 key next to Status to

view alarm message.

Status

Plant

About

Setup Mode

Configuration:

Effective row spacing: 15.0

Front / Rear

1. General Settings

2. Seed Meter Settings

3. Row Unit Alarm Levels

4. Setup Data Logging

5. Configure Planter Monitor

6. Add New Muxbus Sensors

7. Add Single Interplant Row

8. Select Speed Sensor

9. Sensor Setup

10.Calibrate Speed Sensor

Logdata

Seed Rate Alarm

TM

KPM III

M0248

6/13

21

Monitor Operation