Field operation, Kpm iii m0248, 23 monitor operation – Kinze KPM III User Manual

Page 25: Setup mode

Advertising
background image

NOTE: Planter monitor configuration above has an even

number of front (Interplant) rows (8).

STEP 7

Sensor Present Warning – One or more sensors are

present on Muxbus.

Status

Plant

About

Setup Mode

Configuration:

Effective row spacing: 15.0

Front / Rear

1. General Settings

2. Seed Meter Settings

3. Row Unit Alarm Levels

4. Setup Data Logging

5. Configure Planter Monitor

6. Add New Muxbus Sensors

7. Add Single Interplant Row

8. Select Speed Sensor

9. Sensor Setup

10.Calibrate Speed Sensor

Logdata

The planter monitor configuration must
contain an odd number of front rows
before the single leftmost interplant row
unit can be added.

Add Interplant Row Error

OK

Status

Plant

About

Setup Mode

Configuration:

Effective row spacing: 15.0

Front / Rear

1. General Settings

2. Seed Meter Settings

3. Row Unit Alarm Levels

4. Setup Data Logging

5. Configure Planter Monitor

6. Add New Muxbus Sensors

7. Add Single Interplant Row

8. Select Speed Sensor

9. Sensor Setup

10.Calibrate Speed Sensor

Logdata

One or more sensors are present on the
Muxbus.

The monitor can not be reconfigured
until all sensors are disconnected from
the Muxbus.

Sensors Present Warning

OK

F1

F2

F4

F3

MPH

Avg
Pop

0

0.0

1 2 3 4 5 6 7 8 9 10 11 12

1 2 3 4 5 6 7 8 9 10 11 12

120

110

100

90

80

70

60

%

120

110

100

90

80

70

60

%

Contrast

Alarm

Rear Row 1
wake failed
20 more of same type

F1

Ignore this sensor

F2

Keep trying this sensor

F3

Ignore All failed wakes

F4

Keep trying All

Status

Normal

Average

Section

Freeze

0.00

1 2 3 4 5 6 7

1 2 3 4 5 6 7 8

120

110

100

90

80

70

60

%

120

110

100

90

80

70

60

%

ACF

R2
Pop
Scan

0

STEP 8

Alarm: Rear Row 1 wake failed – Select an option

from warning box and press key next to selection.

FIELD OPERATION

Press ON/OFF key to turn monitor ON.

If monitor has been configured, it will show Planter Configuration

screen and attempt to communicate with seed sensors.

NOTE: Do not attempt planting before ‘‘Wait For Calibration’’

message disappears. If planter is moving while sensors are

calibrating alarms will be generated.

NOTE: If monitor can communicate with sensors Planter

Configuration screen displays.

If monitor does not detect sensors message below displays.

NOTE: Selecting OK reconfigures monitor requiring all

sensors to be re-learned. Selecting Cancel keeps current

configuration and monitor continues trying to communicate

with sensors.

RowPop

Spacing

Area

Other

Accuracy

Avg
Pop

0

1 2 3 4 5 6 7 8 9 10 11 12

1 2 3 4 5 6 7 8 9 10 11 12

120

110

100

90

80

70

60

%

120

110

100

90

80

70

60

%

0.66

AC3

Sensors Calibrating

Wait for Calibration...

RowPop

Spacing

Area

Other

Accuracy

Avg
Pop

0

0.00

1 2 3 4 5 6 7 8 9 10 11 12

1 2 3 4 5 6 7 8 9 10 11 12

120

110

100

90

80

70

60

%

120

110

100

90

80

70

60

%

ACT

RowPop

Spacing

Area

Other

Accuracy

Avg
Pop

0

1 2 3 4 5 6 7 8 9 10 11 12

1 2 3 4 5 6 7 8 9 10 11 12

120

110

100

90

80

70

60

%

120

110

100

90

80

70

60

%

0.0

AC3

No Sensors Detected

Reconfigure the planter monitor?

No sensors were detected, but
the planter monitor is configured.

Select OK to reconfigure the monitor.
Select Cancel to retain the current
planter monitor configuration.

Cancel

OK

STEP 6

Add Interplant Row Error – Planter monitor

configuration must contain an odd number of front

rows before single Interplant row unit can be added.

TM

KPM III

M0248

6/13

23

Monitor Operation

Advertising