Display – Klein Tools VDV526-052 User Manual

Page 3

Advertising
background image

3

DISPLAY

1.

Pass: “Pass” illuminates if the cable is a properly wired 4-pair

T568A/B data cable or cross-over (uplink) cable. A cross-over

cable will have the pin numbers of the crossed pairs flashing and

will alternate with “C”.

2.

Cable Faults: The “Miswire” icon illuminates if the cable is not

wired to one of the cabling standards. An open or short error takes

precedence over miswires and the appropriate icon(s) illuminates.

The “Split” icon illuminates if the designated pairs are not twisted

together in the cable, an AC signal fault.

3.

Tester-End Wire Map: The top line displays the pins on the tester

end in order. These pins are mapped to the pins on the remote-end

shown directly below them on the LCD.

4.

Remote-End Wire Map: The bottom line displays the

corresponding pin on the remote-end. Dash lines on the remote

line indicate shorted pins. No pin numbers displayed on the remote

line are open pairs.

5.

Battery Low: The battery low symbol illuminates when the

battery is nearing depletion. The symbol will begin to flash

when the battery needs to be replaced. Results may be unreliable

at this point.

6.

Shield: The “S” icon illuminates when a shielded data cable is

properly connected at both ends. It will be flashing if there is a

short to a wire in the cable along with that pin number and the

“Short” indicator.

7.

Voltage Detected Warning: If voltage is detected on any of the

tester connectors, the “Voltage!” icon illuminates. A check for

voltage is performed before each test and if found, no test is run.

The tester should be disconnected immediately from the source

of the voltage.

1

2

3

4

5

6

7

Advertising