Klein Tools CL3200 User Manual
Page 5

1.
AC Current: < 200A
• Center wire in guides for best accuracy.
• Opposing currents cancel (use line-splitter when necessary).
2.
AC / DC Voltage: < 750V AC or 1000V DC
AC / DC Voltage (Low Z): < 600V
• The tester will automatically choose AC voltage or DC voltage or
AC current based on the inputs detected.
• AUTO will be displayed when no input is detected.
• DO NOT Use low impedance (Low Z) mode at voltages greater
than 600 V.
• Use low impedance (Low Z) mode to reduce ghost voltages.
3. Resistance:
< 40M
Ω
•
Do not measure resistance on a live circuit.
4. Continuity
• Display shows resistance.
• Buzzer sounds if less than about 40
Ω
.
5.
Non Contact Voltage (NCV): > 25V AC
• NCV works independently of other tester functions. The function
knob can be in the off position.
• Press and hold.