Klein Tools CL1200 User Manual

Page 7

Advertising
background image

AC Current Measurement

Range

Resolution

Accuracy

600µA

0.1µA

± (2.0% + 5 digits)

2000µA

1µA

± (1.5% + 5 digits)

60A

0.01A

± (2.9% + 15 digits)

600A

0.1A

± (1.9% + 8 digits)

Overload Protection:

Voltage:

600V RMS

Current: (leads)

2000µA

(clamp)

600A

Frequency:

45 to 400Hz

Minimum Current for Frequency Measurement:

400µA or 20A

Minimum Current for Clamp Measurement: 0.2A

Response:

Averaging

Resistance Measurement

Range

Resolution

Accuracy

600

Ω

˜ 6M

˜˜

Ω

0.1

Ω

˜ 1k

˜˜

Ω

± (1.0% + 4 digits)

60M

Ω

10k

Ω

± (2.0% + 4 digits)

Overload Protection:

600V RMS

Capacitance Measurement

Range

Resolution

Accuracy

60nF ˜ 6000µF

˜˜

0.01nF ˜ 1µF

˜˜

± (3.5% + 6 digits)

Overload Protection:

600V RMS

Frequency Measurement (Voltage)

Range

Resolution

Accuracy

99.99Hz ˜ 499.9kHz

˜˜

0.01Hz ˜ 100Hz

˜˜

± (0.1% + 4 digits)

Overload Protection:

600V RMS

Sensitivity:

2.5V RMS

Duty Cycle Measurement

Range

Resolution

Accuracy

1 ˜ 99%

˜˜

0.1%

± (0.1% + 5 digits)

Overload Protection:

600V RMS

Sensitivity:

1.2Vpp ~ 50Vpp

Frequency Range:

< 500 Hz

Diode Test

Overload Protection Range Test Current

Open Circuit Voltage

600V RMS

6.0V

Appx. 0.25mA

< 1.8V DC

Continuity Test

Overload Protection

Open Circuit Voltage

Threshold (Appx.)

600V RMS

< 0.44V

<40

Ω

Non Contact Voltage Detector

On Voltage

Appx. 25V AC

Specifi cations subject to change.

Advertising