AC

ELECTRICAL SPECIFICATIONS

DC Voltage Measurement

Range

Resolution

Accuracy

200mV

0.1mV

± (0.8% + 2 digits)

2V

0.001V

20V

0.01V

200V

0.1V

600V

1V

± (1.0% + 2 digits)

Overload Protection:

200mV range:

250V DC / AC RMS

2V-600V ranges:

600V DC / AC RMS

Input Impedance:

10M

Ω.

AC Voltage Measurement

Range

Resolution

Accuracy

200mV

0.1mV

± (1.0% + 10 digits)

2V

0.001V

± (1.0% + 5 digits)

20V

0.01V

200V

0.1V

600V

1V

± (1.5% + 5 digits)

Overload Protection:

200mV range:

250V DC / AC RMS

2V-600V ranges:

600V DC / AC RMS

Input Impedance:

10M

Ω

Response:

Averaging

AC Current Measurement

Range

Resolution

Accuracy

2A

0.001A

± (3.5% + 20 digits)

0.5A

2A

0.001A

± (3.0% + 10 digits)

>

0.5A

20A

0.01A

± (3.0% + 10 digits)

200A

0.1A

± (2.5% + 10 digits)

600A

1A

± (1.5% + 5 digits)

Frequency Range:

50 to 60Hz

Response:

Averaging

Resistance Measurement

Range

Resolution

Accuracy

200

Ω

0.1

Ω

± (1.2% + 2 digits)

2k

Ω

0.001k

Ω

20k

Ω

0.01k

Ω

200k

Ω

0.1k

Ω

2M

Ω

0.001M

Ω

20M

Ω

0.01M

Ω

± (2.0% + 5 digits)

Overload Protection:

250V

Open Circuit Voltage:

0.25V

Do not measure resistance on a live circuit.

3.

Diode / Continuity

Diode Features:

HOLD

Display shows:
• Forward voltage drop if forward biased.
• “O.L.” if reverse biased.

4. Resistance:

< 20MΩ

Features:

HOLD

RANGE

Continuity Features:

HOLD

• Display shows resistance.
• Buzzer sounds if less than 60

Ω.

SYMBOLS USED ON LCD

~

AC Measurement

DC Measurement

-

Negative DC Value

MAX

Maximum Reading

Low Battery

AUTO

Auto Range Active

H

Hold Active

A

Current in Amps

V

Voltage Measurement

Diode Test

Ω

Resistance in Ohms

Continuity Test

m

Milli 10

-3

k

Kilo 10

M

Mega 10

6

Advertising