OpErAtiNG iNstructiONs

temperature measurement
To take measurements with your IR2000, aim the instrument at the object

to be measured and pull the trigger. The unit has an auto off after releasing

the trigger of 60 seconds.

targeting
The IR2000 features a dual laser to assist in targeting the area to be

measured. The distance between the two lasers approximates the diameter

of the circular spot focused on by the infrared sensor. This area will

become larger as the target surface moves further away from gun (see

Distance to Spot Ratio for more information). The approximation will be

mostly accurate at a minimum distance of 12" from the IR2000.

selecting temperature scale
Press the Down Key while in display mode or any measurement mode

to alternate between Fahrenheit and Celsius. You can select either scale

during or after measurement, and when viewing any of the held values.

Lock mode (Auto-scan)

In lock mode, the IR2000 will take measurements continously without

holding down the trigger. The trigger can be held down to activate the laser,

but is not required.

Auto Hold

The IR2000 will hold the last temperature measured for 60 seconds after

the trigger is released. To recall this value or associated calculations press

the MODE key to activate the display and show the held temperature.

In probe mode, the unit will automatically power off after 12 minutes. In

auto-scan mode, the unit will automatically power off after 60 minutes.

toggling Laser & Backlight

To toggle the laser, hold down the trigger and press the Down Key. To

toggle the backlight, hold down the trigger and press the Up Key.

thermocouple probe mode

The IR2000 can measure the temperature from a K-Type thermocouple

probe. Press the mode key to enter Probe Mode. The measured

temperature will automatically be displayed. To see the minimum or

maximum temperature taken by the probe, press and hold the Down Button

or Up Button, respectively.

LcD symBOLs

Laser is active

The backlight is on.

The last measurement taken is being shown.

The thermometer is currently taking measurements.

Auto-scan mode is active.
Celsius or Fahrenheit temperature scale.

Battery is OK.

Battery is low and should be replaced.

Battery is exhausted. Replacement necessary before use.

GRAPHICS DRAWING NAME: IR2000-139672TART

GRAPHICS PART NUMBER: 139672T ECN NUMBER.: 10943

PACKAGING DWG. REF.: NA Revision: A