Decals and Antiskid

32410

57 – Outer barrier is not up and latched and

ground detect switch did not deactivate
(Century and Vista only)

58 – Outer barrier is not up and latched and the

platform is 3

"

above the ground

59 – Outer barrier is not up after pausing

platform travel

60 – The kickout gas springs are worn, replace

before using

75 – Low voltage detected; must turn off power

switch to reset LCD

77 – Vehicle secure interlock has not been

activated

90 – Position will be set if you keep holding the

button until it beeps

91 – Position is out of a predetermined

acceptable range of floor position

92 – Bridge switch is not made, needs adjusting
93 – Inner rollstop occupied switch is not made,

position needs to be moved or switch
should be adjusted

94 – Outer barrier is not made, fix and try again
95 – Outer barrier latch is not made (check for

jumper on Century and Vista lifts, check
latch on Millennium lifts)

99 – Controller program is not valid; replace

controller

Flashing Numbers

Flashing 65 – Unfold button is pressed
Flashing 66 – Fold button is pressed
Flashing 67 – Down button is pressed
Flashing 68 – Up button is pressed
Flashing 69 – Bridge switch is activated
Flashing 70 – Outer barrier latch switch is

activated

Flashing 71 – Ground detect switch is activated
Flashing 72 – Outer barrier up switch is activated
Flashing 73 – Inner rollstop up switch is activated
Flashing 74 – Inner rollstop occupied switch is

activated

Flashing 76 – Outboard barrier occupied switch

is activated

Flashing 78 – Threshold tape switch “A” is

activated

Flashing 79 – Threshold tape switch “B” is

activated

Flashing 80 – Position set button is pressed
Flashing 81 – Single function UP / FOLD /

CLOSE button is pressed

Flashing 82 – Single function OPEN / UNFOLD /

DOWN button is pressed

Flashing 87 – CLOSE button is pressed
Flashing 88 – OPEN button is pressed
Flashing 89 – Door full open switch is activated

(or jumper is installed on control
board)

LCD Lift Codes

Listed below are codes that the lift controller
outputs during lift operation. The codes will be
displayed on an LCD screen located on the lift
control board inside the pump module.

Non-Flashing Numbers

01 – Platform stowed
02 – Platform unfolding
03 – Platform unfolding paused
04 – Platform at floor level
05 – Platform beginning to lower
06 – Platform lowering (threshold cannot be

occupied from this point down)

07 – Outer barrier moving to horizontal

position

08 – Platform at ground level
09 – Outer barrier moving to vertical position
10 – Platform raising
11 – Platform raising paused at floor
12 – Platform folding (limited pressure)
13 – Platform folding (full pressure)
14 – Timed fold (cinching lift tite) or (anti-rattle

state)

15 – Platform folding stopped
16 – Paused fold
17 – Platform between ground and 3

"

above

ground

18 – Platform above 3

"

19 – Outer barrier moving to horizontal

postion

20 – The doors are not fully opened (only

applicable when door operators are
installed)

21 – The doors are opening (only applicable

when door operators are installed)

22 – The doors are closing (only applicable

when door operators are installed)

28 – Illegal function/not defined
29 – Interlock fault not recognized (or has

been cleared but a motion button is still
pressed)

30 – Platform location unknown
31 – Platform location transition state;

attempting to locate position

35 – Two or more motion buttons are being

pressed

36 – The retention belt cannot be buckled

while trying to fold or unfold

37 – Motion button being pressed is not a

valid motion

50 – Outer barrier is not up above inboard

barrier locked position

51 – Threshold is occupied when platform is

1

"

or more below floor level

52 – Inner rollstop is not up and locked below

inner rollstop locked position

53 – Inner rollstop occupied sensor is not

activated between floor and inner rollstop
up position

54 – Outer barrier is occupied before it is up
55 – Outer barrier is not latched when above

the inner rollstop locked position
(Millennium only)

56 – Outer barrier is not up and latched and

bridge switch did not deactivate

32410

32201

32201

PLATFORM FOLD
RELIEF VALVE
ADJUSTMENT

Platform Fold
Relief Valve:
See service
manual for
adjustment
procedure.

30787

Improper handling
and/or servicing
procedures may
result in
electrostatic
discharge (ESD)!
ESD may result in
electronic module
damage.

C A U T I O N

30787

Decals

31132

WARNING

31

132

WARNING

Adjust switch as specified
in installation/service
manual.

HYDRAULIC
PRESSURE SWITCH
ADJUSTMENT

Improper hydraulic
pressure switch
adjustment may result
in serious bodily injury
and/or property damage.

27154