Troubleshooting guide – Landoll 9650 Field Cultivator User Manual

Page 84

Advertising
background image

5-2

F-605-0313 Edition

TROUBLESHOOTING GUIDE

SHANK SPRINGS BREAKING

Lower spring pivot bolt too tight.

Lower spring bolt must be loose enough

that spring end casting may pivot freely.

Upper spring bolt too tight.

Should be 1/8 clearance between jam nut

and top spring plate.

Locking jam nut should be tight against

spring end, not top spring plate

SWEEPS NOT CUTTING, LEAVING
SKIPS

Shanks not positioned correctly

Check for proper shank placement

Sweeps not wide enough

Use wider sweeps

Sweeps set too shallow

Increase operating depth

Incorrect sweep angle

Use 47 degree sweeps

Incorrect shank spring adjustment

Adjust spring shank.

Bent/broken/loose shank or sweep

Repair shank or sweep

WINGS FOLD TOO FAST

Restrictors not properly installed in
cylinders

Black restrictor fittings should be in both

ends of outer fold cylinders and rod end
of inner fold cylinders.

HYDRAULIC - LIFT CYLINDERS NOT
FULLY EXTENDING

Lift cylinders not in phase.

Fully extend cylinders and hold hydraulic

lever until all cylinders are fully
extended

Cylinders not installed in proper series.

Cylinders not installed in proper series.

Wing cylinders are smaller diameter
than center cylinders

Hoses not properly connected

Check hose routing

HYDRAULIC - ENTIRE UNIT SETTLING

Tractor valve leaking

Unplug unit from tractor, and check if unit

still settling

Bad fitting/hose

Repair fitting/hose

HYDRAULIC - UNIT SETTLING, ONE
WING RAISING

Center frame cylinder leaking internally on

side of unit that wing is raising.

Repair center frame master cylinder.

HYDRAULIC - WING SETTLING

Wing cylinder leaking

Repair wing cylinder

HYDRAULIC - UNIT WILL NOT
FOLD/UNFOLD

7-pin connector not plugged into tractor

Attach 7-pin connector to tractor

Implement hydraulic lift not fully raised

Fully raise implement to remove weight

from transport lock.

Limit switch incorrectly set.

Verify that limit switch light is ON before

folding/unfolding. If not adjust limit
switch.

Tractor valve not working

Try a different known working valve.

HYDRAULIC - DEPTH CONTROL VALVE
NOT WORKING

Hydraulic hoses not properly connected

Check hose connections

Depth stop contacts depth control valve,
but does not shut off oil.

Valve plumbed incorrectly

Valve leaking internally.

Implement raises, but will not lower

Valve or manifold plumbed incorrectly

WHEEL BEARING FAILURE

Seals not properly installed

Triple-lip seals should be installed with lips

pointing outward away from the hub.

HARROW PLUGS WITH RESIDUE

Harrow set too aggressive

Reduce tine/tooth angle to allow residue to

flow thru harrow

Harrow spring pressure excessive

Harrow operating too deep, reduce spring

pressure/raise harrow.

HARROW REELS PLUGGING

Excessive down pressure

Reels operating too deep, reduce spring

pressure/raise harrow.

HARROW REELS WILL NOT TURN OR
PUSH SOIL

Depth set too deep for loose or wet
conditions

Adjust reel operating depth

Reel bearing failure

Repair reel bearing.

PROBLEM

PROBABLE CAUSE

SOLUTION

Advertising