background image

Technical data

General data and operating conditions
General data

4

l

16

BA 13.0011−EN 1.0

4

Technical data

4.1

General data and operating conditions

4.1.1

General data

Conformity and approval

Conformity

CE

2006/95/EC

Low−Voltage Directive

Approvals

UL/CSA

File no. E210321

Protection of persons and equipment

Degree of protection

See nameplate

Degrees of protection only apply to horizontal installation

All unused plug−in connections must be sealed with
protective caps or dummy connectors.

Earth leakage current

IEC/EN 61800−5−1

> 3.5 mA

Observe stipulations and safety
instructions!

Total fault current

< 100 mA
Earth−leakage circuit breakers of type B can be used.

Thermal class

F (155 °C) IEC 60034

Exceeding the temperature limit weakens or destroys the
insulation

Insulation resistance

IEC/EN 61800−5−1

< 2000 m site altitude: overvoltage category III

> 2000 m site altitude: overvoltage category II

Protective measures

Short circuit on the motor side, earth fault when switching on
the mains and during operation, motor overtemperature
(input for PTC or thermal contact, I

2

t monitoring)

Permissible voltage

IEC/EN 60034−25

1.5 kV peak value
10 kV/

ms speed of increase

Vibration

Up to 2.0 g (20 m/s

2

) without resonance excitation, e.g. of the

fan.

EMC

Noise emission

IEC/EN 61800−3

Depending on the controller, see documentation for the
controller.

Noise immunity