2 operating conditions, Operating conditions, Technical data – Lenze SDSGS User Manual

Page 17

Advertising
background image

Technical data

General data and operating conditions

General data

4

l

17

BA 13.0011−EN 1.0

4.2

Operating conditions

Ambient conditions

Climatic

Transport

IEC/EN 60721−3−2

2K3 (−20 ... +70 °C)

Storage

IEC/EN 60721−3−1

1K3 (−20 ... +60 °C)

< 3 months

1K3 (−20 ... +40 °C)

> 3 months

Operation

IEC/EN 60721−3−3

Without brake −15 °C ... +40 °C
With brake −10 °C ... +40 °C

Without power reduction

> +40 °C

With power reduction see,
catalogue

Site altitude

< 1000 m amsl − without power reduction
> 1000 m amsl < 4000m amsl with power reduction, see
catalogue

Humidity

Average relative humidity 85 %, without condensation

Electrical

The motor connection type depends on the controller

Length of motor cable

See inverter instructions

Length of cable for speed feedback

Mounting conditions

Mechanical

Mounting positions

Motor

Suitable for all mounting positions

Geared motor

Only for the ordered mounting position, see nameplate

ƒ

Other application conditions require a power derating or torque reduction using the
factors listed in table 2 and 3 (see below).

Power derating

Power derating for other application conditions

Cooling air temperature

[°C]

40

45

50

55

60

Power derating [k

υ

]

1.00

0.95

0.90

0.83

0.77

Installation height above sea level
[m]

1000

2000

3000

4000

5000

Power derating [k

h]

1.00

0.92

0.83

0.77

0.67

Tab. 1

Advertising