Commissioning, 2 additional i/o module parameters, Alsv01b 8 – Lenze SV SMV additional I-O module User Manual

Page 11

Advertising
background image

ALSV01B

8

Commissioning

4.2 Additional I/O Module Parameters

In addition to the parameters detailed in the SMVector Frequency Inverter Operating Instructions (SV01),
installing the Additional I/O Module provides access to supplementary parameters exclusive to the Additional
I/O Module. Table 4 lists these supplementary parameters.

Table 4: Additional I/O Module Parameters

Code

Possible Settings

IMPORTANT

No.

Name

Default Selection

P426

p427

TB-13F Input
Function

TB-13G Input
Function

0

0

None

Disables input

1

AUTO Reference: 0-10 VDC

For frequency mode, see P160...P161,
For PID mode, see P204…P205,
For vector torque mode, see P330

2

AUTO Reference: 4-20 mA

RESERVED
4

AUTO Reference: MOP Up

• Normally open: Close input to increase or decrease

speed, PID setpoint or torque setpoint.

• MOP Up is not active while in STOP

5

AUTO Reference: MOP Down

6

AUTO Reference: Keypad

7

AUTO Reference: Network

8

Control Select

Use when P100 = 4, 5 to switch between terminal strip
control and local or remote keypad control.

9

Network Enable

Required to start the drive through the network.

10 Reverse Rotation

Open = Forward Closed = Reverse

11 Start Forward

Refer to Note for typical circuit

12 Start Reverse
13 Run Forward

Refer to Note for typical circuit

14 Run Reverse
15 Jog Forward

Jog Forward speed = P134

16 Jog Reverse

Jog Reverse speed = P135

Active even if P112 = 0

17 Accel/Decel #2

Refer to P125, P126

18 DC Brake

Refer to P174; close input to override P175

19 Auxiliary Ramp to Stop

Normally closed: Opening input will ramp drive to STOP
according to P127, even if P111 is set to Coast (0 or 1).

20 Clear Fault

Close to reset fault

21 External Fault F.EF

Normally closed circuit; open to trip

22 Inverse External Fault F.EF

Normally open circuit; close to trip

WARNING!
Jog overrides all STOP commands! To stop the drive while in Jog mode, the Jog input must be deactivated or a fault condition induced.
NOTE

When input is activated, settings 1...7 override P101

When TB-13A to TB-13D; TB-13F and TB-13G are configured for Auto References other than MOP, TB-13G overrides TB-13F, TB-13F
overrides TB-13D, TB-13D overrides TB-13C, TB-13C overrides TB-13B and TB-13B overrides TB-13A. Any other Auto Reference will
have priority over MOP.

Settings 10...14 are only valid in Terminal Strip mode (P100 = 1, 4, 5, 6)

If Start/Run/Jog Forward and Start/Run/Jog Reverse are both activated, drive will STOP

If Jog input is activated while the drive is running, the drive will enter Jog mode; when Jog input is deactivated, drive will STOP

An F.AL fault will occur if the Assertion Level switch (ALsw) position does not match the P120 setting and any of the digital inputs

(P121...P124, P426 ... P427) are set to a value other than 0.

An F.IL fault will occur under the following conditions:

- TB-13A...TB-13D and TB-13F...TB-13G settings are duplicated (each setting, except 0 and 3, can only be used once)
- One input is set to “MOP Up” and another is not set to “MOP Down”, or vice-versa.
- One input is set to 10 and another input is set to 11…14.
- One input is set to 11 or 12 and another input is set for 13 or 14.

TB-13D and P124 exist in 15HP (11kW) and greater drives only