Electrical installation

Mounting steps

4

l

19

EDKZS3Y200 DE/EN/FR/ES/IT 1.1

4.3

Mounting steps

M

3~

1U1

1U2

1V1

1V2

1W1

1W2

EZS3-xxxA200

xxxx

U

V

W

SSP94SF107

SSP94SF004

SSP94SF109

x

Stripping length depends on the filter size

How to connect the filter:
1. Loosen the four screws

0 and remove the terminal cover 1.

2. Connect the filter input cable to terminals 1U1, 1V1, 1W1.

Connect the filter output cable to terminals 1U2, 1V2, 1W2.

–

Use shielded cables.

–

Connect the two PE conductors to the PE stud using ring cable lugs
(PE connection must comply with EN 50178).

–

Observe tightening torques.

3. Turn down the shield and connect it to the shield sheet (PES) with a surface

as large as possible.

–

Fix the shield with a metal cable tie or hose clip

2.

–

Use an additional cable tie for strain relief

3.

4. Insert the terminal cover

1 and fix it with four screws 0.