2 rated data, Rated data, Technical data – Lenze E94AZMP User Manual

Page 40

Advertising
background image

Technical data

Rated data

4

40

EDK94AZMP DE/EN/FR/ES/IT 7.0

4.2

Rated data

Mains

Voltage

Voltage range

Frequency range

U

Lrated

[V]

U

Lrated

[V]

f [Hz]

3/PE AC

230

180 - 0 % ... 264 + 0 %

45 - 0 % ... 65 + 0 %

3/PE AC

400

320 - 0 % ... 440 + 0 %

45 - 0 % ... 65 + 0 %

3/PE AC

500

400 - 0 % ... 550 + 0 %

45 - 0 % ... 65 + 0 %

Voltage

Freq.

Current [A]

Current [A]

Number

of phases

[V]

[Hz]

max. +45° C

max. +55° C

E94AZMP0084

230/400/500

50/60

8/8/8

6/6/6

3

E94AZMP0294

230/400/500

50/60

29/29/29

21.8/21.8/21.8

3

E94AZMP0294

2)

400/480

50/60

24.5/24.5

15.3/15.3

3

Temperature in the control cabinet

2)

For i700 mounting: mains connection at the bottom, output at the top

Power loss

Inductance

Voltage drop

P

loss

[W]

L [mH]

U [V]

E94AZMP0084

50

3.9

9.8

E94AZMP0294

110

0.7

6.4

Thermal contact

Design

max. switching voltage

max. switching current

U

Th

[V AC]

I

Th

[A]

E94AZMP0084

NC contact, 150 °C

250

2.5

E94AZMP0294

Advertising