3 connection data, Connection data, Electrical installation – Lenze E94AZMP User Manual

Page 52

Advertising
background image

Electrical installation

Connection data

6

52

EDK94AZMP DE/EN/FR/ES/IT 7.0

6.3

Connection data
Mains

Terminal X301

Labelling

Description

L1

L2

L3

Connection of the mains phases L1, L2, L3

Connection for the supply-side PE conductor with M5 ring

cable lug

SSP94NF106

Terminal data

Max. conductor cross-section

Tightening torque

[mm

2

]

[AWG]

[Nm]

[lb-in]

E94AZxP0084

10

6

1.2 ... 1.5

10.6 ... 13.3

PH1

E94AZxP0294

PE connection data

Starting torque

[mm]

[Nm]

[lb-in]

E94AZxP0084

M5

3

26.5

SW 8

E94AZxP0294

Standard device

Cable X302

Labelling

Description

1

2

3

Filter output conductor (lead with wire end ferrule, colour

BK)

PE

Output-side PE conductor (lead with M5 fork-type cable

lug, colour GN/YE)

SSP94FF007