Technical data
Rated data
EDK94AZHN26 DE/EN/FR/ES/IT 1.1
35
l
H1_Daten−Maße_mm
Rated data
Input data
Voltage
Frequency
Current [A]
Number
of
phases
Type
[V]
[Hz]
max. +45 °C
max. +55 °C
E94AZHN0026
400/500
50/60
0.75/0.75
0.61/0.61
1
Temperature in the control cabinet
Output data
Voltage
Frequency
Current [A]
Number
of
phases
Type
[V]
[Hz]
max. +45 °C
max. +55 °C
E94AZHN0026
180/225
0 (DC)
0.75/0.75
0.61/0.61
1
Temperature in the control cabinet
Area
Values
Input voltage
AC 400 V (320 ... 550 V), 45 ... 65 Hz
Output voltage
DC 180 V
With mains voltage of AC 400 V
Brake current
0.1 ... 0.61 A
Cable protection
Recommendation: 5 A, tripping characteristic "B" or "C"
Control input DI
Signalling output DO
Control voltage
DC 24 V, PLC level
HIGH
LOW
DC +15 ... 30 V
DC 0 ... +3 V
Control current
Input 5 ... 10 mA
Output 5 ... 50 mA
Protective function
Protected against polarity reversal up to DC 60 V
Max. connectable cable
cross−section
2.5 mm
2
AWG 12
Maximum cable length
150 m