Technical data

Rated data

2

EDK94AZHN26 DE/EN/FR/ES/IT 1.1

35

l

H1_Daten−Maße_mm

Rated data

Input data

Voltage

Frequency

Current [A]

Number

of

phases

Type

[V]

[Hz]

max. +45 °C



max. +55 °C



E94AZHN0026

400/500

50/60

0.75/0.75

0.61/0.61

1



Temperature in the control cabinet

Output data

Voltage

Frequency

Current [A]

Number

of

phases

Type

[V]

[Hz]

max. +45 °C



max. +55 °C



E94AZHN0026

180/225

0 (DC)

0.75/0.75

0.61/0.61

1



Temperature in the control cabinet

Area

Values

Input voltage

AC 400 V (320 ... 550 V), 45 ... 65 Hz

Output voltage

DC 180 V

With mains voltage of AC 400 V

Brake current

0.1 ... 0.61 A

Cable protection

Recommendation: 5 A, tripping characteristic "B" or "C"

Control input DI
Signalling output DO

Control voltage

DC 24 V, PLC level

HIGH
LOW

DC +15 ... 30 V
DC 0 ... +3 V

Control current

Input 5 ... 10 mA

Output 5 ... 50 mA

Protective function

Protected against polarity reversal up to DC 60 V

Max. connectable cable
cross−section

2.5 mm

2

AWG 12

Maximum cable length

150 m