Electrical installation – Lenze E94AZHN0026 User Manual

Page 41

Advertising
background image

Electrical installation

Connection data

4

EDK94AZHN26 DE/EN/FR/ES/IT 1.1

41

l

H1_E_INST−−−−(DUMMYSEITEVOR)−−−

Control connection

Terminal X117

Labelling

Description

DI

Digital input

GI

GND digital in

DO

Signalling output

24V

24−V supply by safely separated power supply unit
(SELV/PELV)

SSP94A6117

GND

GND digital out

Terminal data

Conductor cross−section

Tightening torque

[mm

2

]

[AWG]

[Nm]

[lb−in]

Flexible

0.5 ... 2.5

20 ... 12

Spring terminal

With wire end
ferrule

Stripping length or contact length: 8 mm

Digital output DO

State

Description

HIGH

No fault

LOW

Fault

l

Supply voltage of the motor holding brake is missing

l

Motor holding brake is not connected

l

Brake cable is defective
– Open circuit
– Short circuit

l

Supply voltage of the motor brake control is missing