Safety instructions

General safety information

1

EDK94AYAD DE/EN/FR/ES/IT 2.0

27

H1sic_EN-UL-Warn_Module_Temp_Fuse

Danger!

Danger to life through improper installation
Improper installation of the safety engineering systems can cause an

uncontrolled restart of the drives.
Possible consequences:

ƒ

Death or severe injuries

Protective measures:
Total cable length between X82 and the connected components (e.g. sensors,

devices, etc.) > 3 m:

ƒ

It is essential to shield the cable installed between X82 and the connected

components:

– Connect the shield at least to the shield support of the installation

backplane.

– If possible, connect the shield to the connected component as well.

Total cable length between X82 and the connected components (e.g. sensors,

devices, etc.) < 3 m:

ƒ

Unshielded wiring is permitted.

Stop!

Before mounting/dismounting, switch off the supply voltage to prevent

electronic modules from damage.

Note!

The entry under code C00214 must correspond to the type of the safety

module plugged on. Otherwise, the controller signals the error: ”Wrong safety

module”.