Electrical installation – Lenze E94AYAD - SM300 User Manual

Page 35

Advertising
background image

Electrical installation

Connection data

4

EDK94AYAD DE/EN/FR/ES/IT 2.0

35

H1_E_INST-Typ4 Kabelquer

X82.3

Labelling

Description

GCL

GND clock output

GI2

GND IN I2A/I2B

I2B

Sensor input 2, channel B (only for passive sensors)

I2A

Sensor input 2, channel A (only for passive sensors)

GCL

GND clock output

GI1

GND I1A/I1B

I1B

Sensor input 1, channel B (only for passive sensors)

I1A

Sensor input 1, channel A (only for passive sensors)

n. c.

This terminal is not assigned.

X82.4

Labelling

Description

GCL

GND clock output

GI4

GND I4A/I4B

I4B

Sensor input 4, channel B (only for active sensors)

I4A

Sensor input 4, channel A (only for active sensors)

n. c.

This part of the terminal strip is not assigned.

Sensor input 3 is not available.

n. c.

n. c.

n. c.

n. c.

Terminal data

Conductor cross-section

Tightening torque

[mm

2

]

[AWG]

[Nm]

[lb-in]

Rigid

0.14 ... 1.5

26 ... 16

Spring terminal

With wire end

ferrule

0.25 ... 0.5

24 ... 20

Advertising