Electrical installation – Lenze E94AYAD - SM300 User Manual
Page 35
Electrical installation
Connection data
4
EDK94AYAD DE/EN/FR/ES/IT 2.0
35
H1_E_INST-Typ4 Kabelquer
X82.3
Labelling
Description
GCL
GND clock output
GI2
GND IN I2A/I2B
I2B
Sensor input 2, channel B (only for passive sensors)
I2A
Sensor input 2, channel A (only for passive sensors)
GCL
GND clock output
GI1
GND I1A/I1B
I1B
Sensor input 1, channel B (only for passive sensors)
I1A
Sensor input 1, channel A (only for passive sensors)
n. c.
This terminal is not assigned.
X82.4
Labelling
Description
GCL
GND clock output
GI4
GND I4A/I4B
I4B
Sensor input 4, channel B (only for active sensors)
I4A
Sensor input 4, channel A (only for active sensors)
n. c.
This part of the terminal strip is not assigned.
Sensor input 3 is not available.
n. c.
n. c.
n. c.
n. c.
Terminal data
Conductor cross-section
Tightening torque
[mm
2
]
[AWG]
[Nm]
[lb-in]
Rigid
0.14 ... 1.5
26 ... 16
Spring terminal
With wire end
ferrule
0.25 ... 0.5
24 ... 20