4 electrical installation – Lenze E94AYAD - SM300 User Manual
Page 32
Advertising
4 Electrical installation
Addressing
EDK94AYAD DE/EN/FR/ES/IT 2.0
32
H1_E_INST-Typ4 Kabelquer
4
Electrical installation
Note!
For installation, the documentation of the controller must be observed.
Addressing
AnunambiguousPROFIsafetargetaddressensuresthatadatatelegramreachesthecorrect
node.
DIP switch
Labelling
1
2
3
4
5
6
7
8
9
0
Value of the address bit
1
2
4
8
16
32
64
128
256
512
Note!
The combination of a safety module SM300 of version VA 1.08 or higher and a
PROFIBUS communication module of version VB 0.93 or higher enables
avoiding the error that occurs when an address is set to 0. For this purpose, a
defined PROFIsafe target address must be stored in C13897 or 14897 of the
PROFIBUS communication module.