Technical data

General data and operating conditions

2

EDK94AZHY DE/EN/FR/ES/IT 2.1

35

l

H1_Daten−E−Daten FN_EN

General data

Conformity and approval

Conformity

CE

2006/95/EC

Low−Voltage Directive

Approval

UR

UL 508C

Industrial Control Equipment Recognised
(file no. E132659) for USA

Protection of persons and equipment

Enclosure

EN 60529

IP00

Protective measures

Against short circuit

EMC

Noise emission

EN 61800−3

Conducted, category C2.

Noise immunity

EN 61800−3

Burst on mains cable:

2 kV/5 kHz

Burst on control cable:

2 kV/5 kHz

Surge on mains cable:

1 kV (1.2

m

s/50

m

s;

phase − phase)

2 kV (1.2

m

s/50

m

s;

phase − PE)