2technical data – Lenze E94AZHY0101 User Manual
Page 38
![background image](/manuals/565788/38/background.png)
Technical data
Rated data
EDK94AZHY DE/EN/FR/ES/IT 2.1
38
l
H1_Daten−E−Daten FN_EN
General electrical data
Area
Values
Input voltage
DC 24 V (18 ... 30 V)
Output voltage
Corresponds to input voltage
Brake current
0.3 ... 5 A
Switching capacity
Max. 110 W
Breaking energy
Max. 10 Ws
Cable protection
Recommendation: 7.5 A, tripping characteristic "B" or "C"
Control input
Control voltage
Internal
Control current
Protective function
Max. connectable cable
cross−section
2.5 mm
2
AWG 12
Maximum cable length
In the chapter "Electrical installation" the dependency of the cable
length on the brake current and the cable cross−section is described.
Operating frequency
Max. 6/min
Operating times
Can be ignored compared to the delay time of the brake.
See documentation of the brake.
Service life
> 10 millions of cycles
Protection against
Overload
No
Short circuit of the
terminals
Yes
Polarity reversal at the
input
Yes
Insulation
1)
Double insulation (EN61800−5−1: V
rated
= 300 V AC),
Separation (UL: V
rated
= 500 V AC)
1)
Brake connection against control card of the controller