Technical data

Rated data

EDK94AZHY DE/EN/FR/ES/IT 2.1

38

l

H1_Daten−E−Daten FN_EN

General electrical data

Area

Values

Input voltage

DC 24 V (18 ... 30 V)

Output voltage

Corresponds to input voltage

Brake current

0.3 ... 5 A

Switching capacity

Max. 110 W

Breaking energy

Max. 10 Ws

Cable protection

Recommendation: 7.5 A, tripping characteristic "B" or "C"

Control input

Control voltage

Internal

Control current

Protective function

Max. connectable cable
cross−section

2.5 mm

2

AWG 12

Maximum cable length

In the chapter "Electrical installation" the dependency of the cable
length on the brake current and the cable cross−section is described.

Operating frequency

Max. 6/min

Operating times

Can be ignored compared to the delay time of the brake.
See documentation of the brake.

Service life

> 10 millions of cycles

Protection against

Overload

No

Short circuit of the
terminals

Yes

Polarity reversal at the
input

Yes

Insulation

1)

Double insulation (EN61800−5−1: V

rated

= 300 V AC),

Separation (UL: V

rated

= 500 V AC)

1)

Brake connection against control card of the controller