Connection data, Electrical installation – Lenze E94AZHY0101 User Manual
Page 45
Advertising
![background image](/manuals/565788/45/background.png)
Electrical installation
Connection data
EDK94AZHY DE/EN/FR/ES/IT 2.1
45
l
H1_E_INST−Verdr_2_BL_EN
Connection data
Terminal X107
Labelling
Description
Connection of the motor holding brake
BD1
BD2
+ (Lenze: WH)
− (Lenze: BN)
E94AZHY0101: 24 V DC, max. 5.0 A
Observe correct polarity!
+ / −
Supply voltage for the motor holding brake (18 ... 30 V DC)
Observe correct polarity!
SSP94X6107
Terminal data
Conductor cross−section
Tightening torque
[mm
2
]
[AWG]
[Nm]
[lb−in]
Flexible
0.5 ... 2.5
20 ... 12
Spring terminal
With wire end
ferrule
Stripping length or contact length: 8 mm