2 rated data, Rated data, Technical data – Lenze E94AZRP0824 User Manual

Page 44

Advertising
background image

Technical data

Rated data

4

44

EDK94AZRP45 DE/EN/FR/ES/IT 5.0

4.2

Rated data

Mains

Voltage

Voltage range

Frequency range

U

Lrated

[V]

U

Lrated

[V]

f [Hz]

3/PE AC

230

180 - 0 % ... 264 + 0 %

45 - 0 % ... 65 + 0 %

3/PE AC

400

320 - 0 % ... 440 + 0 %

45 - 0 % ... 65 + 0 %

3/PE AC

500

400 - 0 % ... 550 + 0 %

45 - 0 % ... 65 + 0 %

Voltage

Freq.

Current [A]

Current [A]

Number

of phases

[V]

[Hz]

max. +45° C

max. +55° C

E94AZRP0824

230/400/500

50/60

82/82/82

61/61/61

3

E94AZRP2004

230/400/500

50/60

200/200/200

150/150/150

3

E94AZRP0824

2)

400/500

50/60

49/49

30.6/30.6

3

Temperature in the control cabinet

2)

For i700 mounting: mains connection at the bottom, output at the top

Power loss

Inductance

Voltage drop

P

loss

[W]

L [mH]

U [V]

E94AZRP0824

80

-

-

E94AZRP2004

150

-

-

Advertising