Mechanical installation

Mounting steps

5

52

EDK94AZRP45 DE/EN/FR/ES/IT 5.0

Use with 9400
Proceed as follows for the installation:
1. Prepare M5 threaded holes on the mounting plate, for instance according

to the mounting grid.

Always use all mounting points specified.

2. Screw the filter onto the mounting plate.

Use M5 screw and washer assemblies or M5 hexagon socket screws

with washers.

If further devices are to be mounted directly adjacent on the right-hand

side of the filter, do not tighten the screws fully before all devices are

mounted and aligned.

Tightening torque: 3.4 Nm (30 lb-in).

Use with i700
How to proceed during mounting:
1. Prepare M5 threaded holes on the mounting plate.

Always use all fixing points specified.

2. Screw the filter to the mounting plate.

Use M5 screw and washer assemblies or M5 hexagon socket screws

with washers.

Tightening torque: 3.4 Nm (30 lb-in).