3 telegram example: read request, Telegram example: read request, 9parameter data transfer – Lenze E94AYCER User Manual
Page 63

Lenze · E94AYCER communication module (PROFINET®) · Communication Manual · DMS 9.0 EN · 12/2013 · TD17
63
9
Parameter data transfer
9.2
Reading parameters from the drive
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
9.2.3
Telegram example: Read request
The heatsink temperature of the inverter is to be read.
• Code to be read: C00061
• Heatsink temperature: 43 °C
Parameter request
Byte 1
Byte 2
Byte 3
Byte 4
Request reference
Request identification
Axis
Number of indices
0xXX
0x01
0x00
0x01
Request parameters for reading
Byte 5
Byte 6
Attribute
Number of subindices
0x10
0x00
Value
No subindex
Byte 7
Byte 8
Byte 9
Byte 10
Index
Subindex
High byte
Low byte
High byte
Low byte
0x5F
0xC2
0x00
0x00
Index = 24575 - code no. = 24575 - 61 = 24514 = 0x5F C2
No subindex