9parameter data transfer – Lenze E94AYCER User Manual
Page 70

9
Parameter data transfer
9.3
Writing parameters to the drive
70
Lenze · E94AYCER communication module (PROFINET®) · Communication Manual · DMS 9.0 EN · 12/2013 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Parameter response to a correctly executed write request
Parameter response after write error
Byte 1
Byte 2
Byte 3
Byte 4
Request reference
Response identification
Axis
Number of indices
0xXX
0x02
0x00
0x01
(mirrored)
Parameter has been written
(mirrored)
1 index
Byte 1
Byte 2
Byte 3
Byte 4
Request reference
Response identification
Axis
Number of indices
0xXX
0x82
0x00
0x01
(mirrored)
Parameter has not been written
(mirrored)
1 index
Byte 5
Byte 6
Format
Number of values
0x44
0x01
Error
Error code without additional
information
Byte 7
Byte 8
Error code
High byte
Low byte