Protective insulation, 6technical data – Lenze E82ZAFFC001 User Manual
Page 38
![background image](/manuals/565947/38/background.png)
Technical data
Protective insulation
EDK82ZAFFC−001 DE/EN/FR 6.0
38
l
H1_Daten−bemessDat
Ambient conditions
Operation 3 K3 acc. to IEC/EN 60721−3−3
− 20 ... + 60 °C
Degree of pollution
2 acc. to IEC/EN 61800−5−1
Enclosure
IP20
X3.2/
Level
DI2
Input resistance: 3.3 k
W
0 = LOW (0 V DC − 0% ... +3 V DC + 0%)
1 = HIGH (+12 V DC − 0% ... +30 V DC + 0%)
Reference: GND
DI3
X3.3/
Level
28
Input resistance: 3.3 k
W
Controller inhibit
l
Start = HIGH (+12 V DC − 0% ... +30 V DC + 0%)
l
Stop = LOW (0 V DC − 0% ... +3 V DC + 0%)
20
Max. load: 70 mA
Reference: GND ASi
Protective insulation
Insulation voltage between bus and ...
Type of insulation
(to EN 61800−5−1)
l
8200 vector/motec power stage
Double insulation
l
Reference earth/PE
Functional insulation
l
Terminal X3.2/DI2 or X3.2/DI3
Functional insulation
l
Terminal X3.3/20
No insulation
l
Terminal X3.3/28
Functional insulation