Data transfer, 5commissioning – Lenze E82ZAFFC010 User Manual

Page 34

Advertising
background image

5

Commissioning

Data transfer

EDK82ZAFFC−010 DE/EN/FR 5.0

34

l

H2datentransfer−Beispiel_zu_Datentransfer

Data transfer

Transfer of AS−i data bits (D0 ... D3) to drive

Assignment D0 ... D3

Configuration of the digital controller inputs E1 ... E4

D0 = E1

à See documentation for controller: Code C0007

D1 = E2

D2 = E3

D3 = E4

Transfer of AS−i data bits (D0 / D1) from drive

Assignment D0 / D1

Configuration of the digital controller output A1

D0 = A1

à See documentation for controller: Code C0117

D1 = 0:
Drive is disconnected from
the mains

D1 = 1:
Drive is supplied by the mains

Transfer of AS−i data bits (D2 / D3) from digital inputs

Assignment D2 / D3

Configuration of the digital inputs DI2 and DI3 of the AS−i / S
function module

D2 = DI2

User−defined

D3 = DI3