Technical data

Protective insulation

6

EDK82ZAFFC−010 DE/EN/FR 5.0

37

l

H1_Daten−bemessDat

Ambient conditions

Climatic conditions

Storage 1 K3 acc. to IEC/EN 60721−3−1

− 25 ... + 60 °C

Transport 2 K3 acc. to IEC/EN 60721−3−2

− 25 ... + 70 °C

Operation 3 K3 acc. to IEC/EN 60721−3−3

− 20 ... + 60 °C

Degree of pollution

2 acc. to IEC/EN 61800−5−1

Enclosure

IP20

X3.2/

Level

DI2

Input resistance: 3.3 k

W

0 = LOW (0 V DC − 0% ... +3 V DC + 0%)
1 = HIGH (+12 V DC − 0% ... +30 V DC + 0%)
Reference: GND

DI3

X3.3/

Level

28

Input resistance: 3.3 k

W

Controller inhibit

l

Start = HIGH (+12 V DC − 0% ... +30 V DC + 0%)

l

Stop = LOW (0 V DC − 0% ... +3 V DC + 0%)

20

Max. load: 70 mA
Reference: GND ASi

Protective insulation

Insulation voltage between bus and ...

Type of insulation

(to EN 61800−5−1)

l

8200 vector/motec power stage

Double insulation

l

Reference earth/PE

Functional insulation

l

Terminal X3.2/DI2 or X3.2/DI3

Functional insulation

l

Terminal X3.3/20

No insulation

l

Terminal X3.3/28

Functional insulation