Electrical installation

Connect spring-operated brake

EDK82ZWBRU DE/EN/FR 2.0

41

L

15m

m

1

2

3

1

4

2

3

0 1

2 3

4

-18-

82ZWBRU007



Screw cap



Crown



Sealing rubber



Splicing ring



Contact carrier

Splicing ring assignment

Control of spring-loaded brake

1 / 3

Spring-loaded brake is switched by control input

1 / 2

Spring-loaded brake is switched by mains voltage (control input
is without function)

Assembly and connection of brake line
1. Remove 15 mm of cable sheathing.
2. Push screw cap

, crown  and sealing rubber  onto cable.

3. Insert core ends in the entry of the splicing ring

. The entries are labelled with 1, 2,

3. Cut off projecting core ends (the maximum projection of the core ends from the
splicing ring must not exceed 2 mm).

4. Insert the prepared conductor in the contact carrier

 and tighten screw cap .

Note!

The splicing ring is coded and will only fit in one position.