6

Technical data

General data/Rated data

EDK82ZWBRU DE/EN/FR 2.0

L

42

General data

Conformity

CE

Low-Voltage Directive (37/23/EC)

Resistance to
vibration

Acceleration-proof to 2g
(Germanischer Lloyd, general conditions)

Climate
conditions

Class 3K3 according to EN 50178
(without moisture condensation, medium RH 85% )

Degree of
contamination

VDE 0110 Part 2 Degree of contamination 2

Temperature ranges

Transport
Storage
Operation

-25

°C ... +80 °C

-25

°C ... +80 °C

-20

°C ... +60 °C

Installation

in Lenze base units

RFI emission

Limit class A according to EN55011

Insulation resistance

Overvoltage category III according to VDE0110

Enclosure

IP65

Rating

Input voltage

1/N/PE AC 230 V, 45 Hz ... 65 Hz
3/PE AC 230 V, 45 Hz ... 65 Hz
3/PE AC 400 V, 45 Hz ... 65 Hz
3/N/PE AC 400 V, 45 Hz ... 65 Hz
3/N/PE AC 500 V, 45 Hz ... 65 Hz

Output voltage

DC 205 V

with mains voltage AC 230 V

Output voltage

DC 180 V / DC 205 V

with mains voltage AC 400 V

DC 257 V

with mains voltage AC 500 V

Brake current

max. 0.55 A

Power loss

max. 3 W

Control input

High (DC +12 ... 30 V)
Low (DC 0 ... +3 V)
(PLC level, HTL)

Brake switching
times

see technical data of the brake

Show/Hide Bookmarks