Jumper positions for inputs, C0034/1 = 1, jumper in position "7 − 9, 5commissioning – Lenze E82ZAFAC001 User Manual

Page 38

Advertising
background image

5

Commissioning

Jumper positions for inputs

EDK82ZAFAC−001 DE/EN/FR 5.0

38

l

H1inbet−Jmpausgg

Jumper positions for inputs

10

9

8

7

2

1

4

3

6

5

Lenze setting (bold printing in tables)

Ÿ 1 − 3
Ÿ 2 − 4
Ÿ 7 − 9
Ÿ 8 − 10

)

Note!

If a setpoint potentiometer is supplied internally via X3.2/9, the jumper must
be set between 0 ... +5 V. Otherwise it is not possible to use the whole speed
range.

Analog inputs

Possible levels

0 ... +5 V

0 ... +10 V

−10 ... +10 V

X3.1/1U
Analog input 1, AIN1

Jumper

7 − 9: free

7 − 9

7 − 9

Code

C0034/1 = 0

C0034/1 = 0

C0034/1 = 1

X3.1/2U
Analog input 2, AIN2

Jumper

8 − 10: free

8 − 10

8 − 10

Code

C0034/2 = 0

C0034/2 = 0

C0034/2 = 1

Analog inputs

Possible levels

0 ... +20 mA

+4 ... +20 mA

+4 ... +20 mA

1)

X3.1/1I
Analog input 1, AIN1

Jumper

optional

optional

optional

Code

C0034/1 = 2

C0034/1 = 3

C0034/1 = 4

X3.1/2I
Analog input 2, AIN2

Jumper

optional

optional

optional

Code

C0034/2 = 2

C0034/2 = 3

C0034/2 = 4

1)

open−circuit monitored