Mechanical installation

Mounting steps

3

EDK82ZM113−001 DE/EN/FR 1.1

35

l

H1_MechINS−Montage_Var_E82ZM−001

How to mount the filter:
1. Put the frequency inverter

0 on the housing of the motor interference suppression

module

1.

2. Move the frequency inverter to the fixing rail of the motor interference suppression

module.

3. Move the fixing rail

2 to the heatsink slot of the standard device and screw the

frequency inverter and the motor interference suppression module together.

4. Connect the connecting cable of the motor interference suppression module

3 to the

terminals of the standard device (U, V, W, and PE). (

^ 38). Observe the

documentation of the standard device!

5. Mount the unit to the control cabinet.