3

Mechanical installation

Mounting steps

EDK82ZM113−001 DE/EN/FR 1.1

36

l

H1_MechINS−Montage_Var_E82ZM−001

Mounting variant



‚

2

1

0

3

E82ZM−003b

How to mount the filter:
1. Apply the motor cable

0 since for some types the terminals are no longer accessible

after a mechanical mounting.
– Apply the motor cable to the terminals U’, V’, W’

1 and to the PE screw2,

respectively. (

^ 38).

– Apply the motor cable shielding extensively to the shield connection on the right

hand side and fix it using the shield clamp

3(included in the scope of supply).

2. Mount the interference suppression module to the control cabinet to the right of the

standard device.
This is the only way to avoid loops.