Electrical installation – Lenze E82ZAFBC201 User Manual

Page 39

Advertising
background image

Electrical installation

Wiring

5

EDK82ZAFBC−201 DE/EN/FR 5.0

39

l

H1_E_INST−INS_Klemmenbeleg

X3/

Signal type

Function

Level

(Lenze setting: Bold print)

62

Analog
output

Output frequency

0 … +6 V
0 … +10 V

1)

7

GND1,

reference potential for analog signals

8

Analog
input

Input for actual value or setpoint
Change range using the DIP switch and C0034

l

Voltage signal

0 … +5 V
0 … +10 V
−10 V … +10 V

2)

l

Current signal

0 … +20 mA
+4 … +20 mA
+4 … +20 mA (open−circuit
monitored)

9

Internal, stabilised DC voltage supply for setpoint
potentiometer

+5.2 V

20

Internal DC voltage supply for control of digital
inputs and outputs

+20 V ±10 % (ref.: X3/7)

28

Digital
inputs

Controller inhibit (CINH)

1 = enable

E1

3)

Activation of JOG frequencies
JOG1 = 20 Hz
JOG2 = 30 Hz
JOG3 = 40 Hz

E1

E2

JOG1

1

0

E2

3)

JOG2

0

1

JOG3

1

1

E3

DC−injection brake (DCB)

1 = DCB

E4

Change of direction of rotation
CW/CCW rotation

E4

CW

0

CCW

1

39

GND2,

reference potential for digital signals

A1

Digital
output

Ready for operation with

– internal supply:
– external supply:

0 … +20 V
0 … +24 V

59

DC supply for X3/A1

– internal (jumper to X3/20):
– external:

+20 V
+24 V

1)

Output level 0 … +10 V: Adapt offset (C0109/C0422) and gain (C0108/C0420)

2)

Adjust offset (C0026) and gain (C0027) separately for each function module:
After replacing the function module or the standard device
After loading the Lenze setting

3)

Alternatively frequency input 0 … 10 kHz single−tracked or 0 ... 1 kHz double−tracked, configuration
via C0425

Advertising