Safety instructions

Residual hazards

EDKRBM390R DE/EN/FR/ES/IT 3.0

30

l

H1sic_EN−UR_Warn

Residual hazards

{

Danger!

Dangerous electrical voltage

The terminals of the brake resistor may carry
dangerous voltages during operation of the basic
device and up to three minutes after mains
disconnection.

Possible consequences:

ƒ

Death or severe injuries when touching the
terminals.

Protective measures:

ƒ

Before working on the brake resistor disconnect
the basic device from the mains.

ƒ

Check all power terminals for safe isolation from
supply.

ƒ

Select the mounting location so that the
operating conditions mentioned in the technical
data are always ensured.

}

Danger!

Hot surface

The brake resistor may get very hot. (Temperatures
are listed in the chapter "Technical data".)

Possible consequences:

ƒ

Severe burns when touching the brake resistor.

ƒ

Fire or smouldering fire if flammable materials or
substances are placed near the brake resistor or
may get to it.

Protective measures:

ƒ

Before working on the brake resistor check its
surface temperature.

ƒ

Select the mounting location so that the
operating conditions mentioned in the technical
data are always ensured.

ƒ

Protect the mounting location by suitable fire
prevention and protection against contact.

ƒ

Apply clearly visible label with a "Caution, hot
surface" safety note on the protection against
contact.