Mounting steps, Electrical installation – Lenze ERBMxxxRxxxW User Manual

Page 43

Advertising
background image

Electrical installation

Mounting steps

6

EDKRBM390R DE/EN/FR/ES/IT 3.0

43

l

H1_E_INST−Mech Installation Aufkleber_en

Mounting steps

ERBM82−004

How to connect the brake resistor:
1. Disconnect the standard device from the mains and check

all power terminals for safe isolation from supply.

2. Connect brake resistor cables

0 (RB1, RB2: transparent lead)

and thermal contact cable

1 (T1, T2: white lead) (see

documentation for standard device).
– If the prepared connecting cables are long enough, twist

them. (See connection plan, variant 1)

– If longer cables are required (max. 5 m), shorten the

prepared cables to at least 10 cm and connect them to
external terminal connections. From there on, use
shielded cables. (See connection plan, variant 2)

– When integrating the thermal contact into the system

monitoring, ensure that the mains supply will be
switched off when the brake resistor is overheated.

3. Mount PE conductor to PE stud (M4)

2 with ring cable lug.

– Implement PE connection in accordance with EN

61800−5−1.

– Observe tightening torque!

4. Place warning sticker

3 close to the device in a clearly

visible manner!

Advertising