Rated data, 4technical data – Lenze ERBMxxxRxxxW User Manual

Page 38

Advertising
background image

4

Technical data

Rated data

EDKRBM390R DE/EN/FR/ES/IT 3.0

38

l

H1_Daten−FN_Toleranz +30mm

Rated data

Electrical data

R

B

P

d

Q

B

U

max

[

W

]

[W]

[kWs]

[V

DC

]

ERBM020R150W

20

150

13

800

ERBM039R120W

39

120

6

ERBM100R100W

100

100

15

400

ERBM180R050W

180

50

7.5

ERBM390R100W

390

100

15

800

R

B

Resistance

P

d

Permanent power

Q

B

Heat quantity

U

max

Max. operating voltage

Temperatures

T

nom

T

TK

T

max

[°C]

On the surface

200

300

500

On the clearance
edge

*)

90

100

120

T

nom

Maximum temperature for rated data

T

TK

Temperature at which the thermal contact is activated

T

max

Maximum temperature in the case of improper use

*)

Measured for air as the ambient medium (small coefficient of
thermal conductivity); if materials which heat up are located
at the clearance edge (greater coefficient of thermal
conductivity), the temperature continues to rise.

Advertising