Troubleshooting and fault elimination – Lenze 8200 vector 15kW-30kW User Manual

Page 22

Advertising
background image

Troubleshooting and fault elimination

Fault messages on the keypad or in the parameter setting program Global Drive Control

3

l

22

EDK82EV303 EN 1.0

Remedy

Cause

Fault

PC

1)

Keypad

OH3

a

53

PTC monitoring (TRIP)
(Display when
C0119 = 1 or 4)

Motor too hot due to impermissibly
high currents or frequent and too long
acceleration processes

Check drive dimensioning

No PTC connected

Connect PTC or switch off monitoring

OH4

a

54

Controller
overtemperature

Controller too hot inside

l

Reduce controller load

l

Improve cooling

l

Check fan in the controller

OH51

203

PTC monitoring
(Display when
C0119 = 2 or 5)

Motor too hot due to impermissibly
high currents or frequent and too long
acceleration processes

Check drive dimensioning

No PTC connected

Connect PTC or switch off monitoring

OU

c

DC bus overvoltage
(Message or TRIP
configurable in C0310)

Mains voltage too high

Check supply voltage

OUE

a

22

Braking operation

l

Increase deceleration times

l

When operating with an external brake
resistor:
– Check dimensioning, connection and

supply cable of the brake resistor

– Increase deceleration times

Earth leakage on the motor side

Check motor supply cable and motor for
earth fault (disconnect motor from the
inverter)

Pr

a

75

Faulty parameter
transfer with the
keypad

All parameter sets are defective

Before enabling the controller, repeat the
data transfer or load the Lenze setting

Pr1

a

72

Faulty PAR1 transfer
with keypad

Parameter set 1 is defective

Pr2

a

73

Faulty PAR2 transfer
with keypad

Parameter set 2 is defective

Pr3

a

77

Faulty PAR3 transfer
with keypad

Parameter set 3 is defective

Pr4

a

78

Faulty PAR4 transfer
with keypad

Parameter set 4 is defective

Pr5

a

79

Internal fault

EEPROM is defective

Contact Lenze

PT5

a

81

Time error during
parameter set transfer

Data flow from keypad or PC
interrupted, e.g. because keypad was
disconnected during transfer

Before enabling the controller, repeat the
data transfer or load the Lenze setting.

rST

a

76

Error during auto TRIP
reset

More than 8 error messages within
10 minutes

Depends on the error message

sd5

a

85

Open circuit − analog
input 1

Current at analog input < 4 mA at
setpoint range 4 ... 20 mA

Close circuit at analog input

sd7

a

87

Open circuit − analog
input 2

1)

LECOM error number, display in Global Drive Control (GDC) parameter setting program

Advertising